TRACE
A platform for rare eye disease detection

A new perspective on the unseen

Move your cursor and the eye follows. Click anywhere to flash it and watch the pupil react.

Begin the journey ↓Run the demo →
Scroll to travel inside
01 — Cornea

The first lens

Light enters through a clear dome that handles roughly two-thirds of the eye’s focusing power. The glint you see follows your cursor, just like a window reflecting on real glass.

02 — Pupil

Through the pupil

03 — Retina

Where the signal begins

A drawn illustration of the back of the eye (not a real photo, and not a TRACE output). It shows the kind of signs TRACE’s 20 finding detectors are trained to notice, such as disc swelling, haemorrhages, drusen and media haze, so a clinician can review them.

04 — The model

From a retina photo to a decision

How TRACE reads one fundus photo, step by step.

1 · CheckA quality gate asks for a retake if the photo cannot be read. The retina is found and centred, whatever the camera.
2 · PrepareUneven lighting is flattened and local contrast lifted. Colour is kept: a pale disc or a yellow exudate is evidence.
3 · EncodeA frozen ResNet-50, trained without disease labels on 22,500 photos from many cameras, turns the photo into 2,048 numbers.
4 · DecideCalibrated findings, evidence for and against each disease, and similar past cases. TRACE diagnoses only when sure; otherwise it short-lists or refers. (Example values.)

Earlier insight starts with looking differently.

TRACE is a research prototype built for the ZEISS India Campus Hackathon “Beyond Code 2026”. It supports, and never replaces, an eye-care professional.

05 — Try it

Run it on your own photos

The demo runs TRACE on your own computer (a laptop CPU is enough, about 1 s per photo): a quality check, the findings it sees, the evidence for and against each disease, the five most similar confirmed cases, and a decision to diagnose, short-list or refer.

How to run the demo →
0.92AUROC on a camera never seen in trainingRFMiD, Kowa VX-10α held out. ImageNet ResNet-50: 0.87
63%top-1 over 39 diseases from 5 photos eachJSIEC-1000, a dataset never trained on. Supervised ResNet-50: 57%
90%of TRACE’s diagnoses are rightRFMiD + RFMiD 2.0 test. Unsure photos are short-listed or referred instead
0%of rare-disease photos confidently misdiagnosed63 held-out AION, CRVO and RP photos; 89% referred to a specialist, the right rare disease named on 54

Measured on held-out test photos with the encoder frozen. Intervals, baselines and failures are in MODEL_CARD.md.